Since 2001, Mass Notification Systems (MNS) have become prevalent. Why? Building owners and risk managers understand the potential impact of non-fire related emergencies in their facilities. Real-time communication during an emergency is critical and a comprehensive MNS allowing communication over a variety of mediums, including in-building paging, email, text messaging and social media has become the industry standard.  An increasingly common method to provide in-building notification is to utilize the existing fire alarm system. 

Using a fire emergency voice/alarm communication system (EVACS) as a component of an MNS is a cost-effective solution as it eliminates the need for a separate communication system within a building. Unfortunately, to effectively provide emergency communications during non-fire events, it’s not appropriate to simply have an EVACS fire alarm system.

NFPA 72, which governs fire alarm and MNS design, permits the use of an EVACS for mass notification only after a risk analysis has been completed and the building’s emergency response plan has been approved by the local jurisdiction. Fire alarm systems are designed to notify tenants of a fire-event; and using them in a non-fire event without proper risk analysis and a comprehensive plan can create communication and efficacy issues.

Proper risk analysis and an emergency response plan are also important because they identify potential emergencies and determine how the MNS can and should be used during each event. Certain events must be prioritized over others, allowing communication channels to remain open and effective in an emergency. Identification of potential emergencies and the response capabilities of the EVACS must also be tailored to the specific organizations, locations, and various languages and cultures. Building owners that believe their traditional EVACS system is a tool for emergency communication may find they have limited control over the system when an emergency arises. 

Who can perform the risk analysis? A fire alarm designer or electrical engineer has the required expertise, s/he may complete the risk analysis as part of the design process. NFPA 72 offers requirements and guidance for how to perform these analyses. If the designer does not feel comfortable, or the owner is looking for a designer with more specific expertise, a fire protection engineer can also assist. 

Use of a fire alarm system for in-building emergency communication can be a powerful and cost-effective tool. A risk analysis is code-required and can be used to greatly improve the efficacy of the system and increase occupant safety.

Andy Shanahan is a senior project manager at WB Engineers+Consultants, Boston.

READ ON THE GO
DIGITAL EDITIONS
Subscribe
STAY INFORMED FOR $9.99/Mo.
NEREJ PRINT EDITION
Stay Informed
STAY CONNECTED
SIGN-UP FOR NEREJ EMAILS
Newsletter
Columns and Thought Leadership
Shawmut Design and Construction breaks ground on the 195 District Park Pavilion in Providence, RI

Shawmut Design and Construction breaks ground on the 195 District Park Pavilion in Providence, RI

Providence, RI Shawmut Design and Construction celebrated the ceremonial groundbreaking for the 195 District Park Pavilion, marking the start of construction on a facility that will feature year-round dining and support space for park operations. In addition to the 3,500 s/f building, the project will include infrastructure upgrades
The New England Real Estate Journal presents<br> the First Annual Project of the Year Award! Vote today!

The New England Real Estate Journal presents
the First Annual Project of the Year Award! Vote today!

The New England Real Estate proud to showcase the remarkable projects that have graced the cover and center spread of NEREJ this year, all made possible by the collaboration of outstanding project teams. Now, it's time to recognize the top project of 2024, and we need your vote!
Investing in a falling rate environment - by Harrison Klein

Investing in a falling rate environment - by Harrison Klein

Long-term interest rates have fallen by 100 basis points, and the market is normalizing. In December of 2022 I wrote an article about investing in a high interest rate, high inflation market. Since then, inflation has cooled off, and the Fed has begun lowering their funds rate.
The 2024 CRE markets: “The Ups” (industrial) and “The Downs” (Boston class B/C office) - by Webster Collins

The 2024 CRE markets: “The Ups” (industrial) and “The Downs” (Boston class B/C office) - by Webster Collins

The industrial markets have never been stronger. What has happened is that the build out of Devens with new high-tech biotech manufacturing with housing to service these buildings serves as the connector required to really make the I-495 West market sizzle. Worcester has been the beneficiary